Winter Is the Honest Season: Modelling November to February Properly
In short This article argues that models validated on summer data hide their errors, and shows how to check a forecast against the low-sun months where diffuse fraction, shading and low irradiance thresholds dominate.
If your solar model looks brilliant in June, that tells you almost nothing. Summer is forgiving. The sun is high, the sky is mostly direct beam, and a dozen sloppy assumptions cancel each other out. Winter is where they stop cancelling.
So here is the position of this post: a forecast that has only been validated on April to September data has not been validated. The low-sun months expose the three things that summer hides: diffuse fraction, shading, and the low-irradiance behaviour of your panels and inverter. If your model survives November to February, you can trust it. If it doesn’t, you have found out cheaply, before you price a battery on it.
Why summer flatters you
Take a typical 4 kWp south-facing array in the Midlands, 35 degrees tilt. A quick PVGIS run (the European Commission’s free tool, which has UK coverage) gives roughly these monthly yields:
| Month | PVGIS estimate (kWh) | Share of year |
|---|---|---|
| Dec | 45 | 1.3% |
| Jan | 56 | 1.6% |
| Jun | 520 | 14.8% |
| Jul | 510 | 14.5% |
| Year | ~3,500 | 100% |
(Treat these as illustrative round numbers; your postcode and tilt will move them.)
June is about ten times December. That ratio is the problem. A 10% error in June is 52 kWh, which is invisible in a bill. A 10% error in December is 4.5 kWh, which is also small, but the causes of winter error are not proportional. They are structural. A model with a 3% error in summer can be 30% out in December, because the thing it gets wrong matters more as the sun drops.
Percentage error is also the wrong lens if you are sizing a battery or pricing an export tariff. In winter your array rarely exceeds your base load, so every kWh is self-consumed and worth the full import rate (around 25p to 27p per kWh under the current price cap, versus roughly 4p to 15p for export depending on tariff). Winter kWh are your most valuable kWh. Getting them wrong costs more per unit than getting June wrong.
Error source one: diffuse fraction
In June on a clear day, most of what reaches your panels is direct beam. In December in Manchester, a large share of irradiance is diffuse: light scattered by cloud, arriving from the whole sky dome. Typical diffuse fractions for the UK run around 45% to 50% across the year, but in December and January they commonly sit at 60% to 70%, and on an overcast day they approach 100%.
Why this breaks models:
- Tilt and orientation matter differently. Direct beam cares enormously about your azimuth. Diffuse light barely does. A model that assumes a clear-sky beam component will over-reward a perfect south roof and under-reward an east/west one in winter.
- Transposition models disagree. Converting horizontal irradiance to the tilted plane uses a sky model. Isotropic (Liu-Jordan) treats the sky as uniform. Perez and Hay-Davies add circumsolar and horizon brightening. Isotropic tends to under-predict on a low-sun, clear winter day and behaves differently under overcast.
- Clear-sky tools lie by construction. Anything that starts from a clear-sky curve and applies a flat “cloud factor” will not capture December’s diffuse behaviour.
A check you can run
Pull your own monthly generation from your inverter app (SolarEdge monitoring, Enphase Enlighten, SolaX Cloud, whichever you have) and compare with a model that lets you choose the transposition method. In pvlib (Python), the comparison is a few lines:
import pvlib
loc = pvlib.location.Location(52.5, -1.9)
times = pd.date_range("2025-12-01", "2025-12-31 23:00", freq="h", tz="Europe/London")
# weather from PVGIS TMY or your own irradiance source
for model in ["isotropic", "haydavies", "perez"]:
poa = pvlib.irradiance.get_total_irradiance(
35, 180, solpos.apparent_zenith, solpos.azimuth,
dni, ghi, dhi, dni_extra=dni_extra, model=model)
print(model, round(poa["poa_global"].sum() / 1000, 1), "kWh/m2")
Typical output for a December on that Midlands roof might look like this:
isotropic 21.4 kWh/m2
haydavies 23.8 kWh/m2
perez 24.6 kWh/m2
That is a 15% spread from one setting, in a month where the total is small. In June the same three models agree to within about 3%. Winter is where you find out which one matches your meter.
Error source two: shading you never noticed
A chimney that shades nothing in June will shade a corner of your array from 10am to 1pm in December. At 52 degrees north the noon sun on 21 December is only about 14 degrees above the horizon. A neighbour’s roof ridge 12 metres away and 5 metres higher blocks a sun at roughly 22 degrees. That is enough.
Shading in winter is also disproportionately costly because of how strings work. If a panel on a string is partly shaded, and you have no optimisers or microinverters, the whole string’s current is limited by the weakest panel. Bypass diodes help, but a few percent of shaded area can cost 20% or more of the string’s output in that hour.
How to model it
- Use a horizon profile. PVGIS lets you upload or auto-calculate a horizon from terrain data, but it does not know about your neighbour’s extension. Walk outside with a free app such as Sun Seeker or Sun Surveyor and photograph the horizon, then enter elevation values at each azimuth.
- Compare a modelled “no shade” December to your actual. A gap that is large in December and vanishes in March is your signature.
- Check the shape of the day, not just the total. Export 15-minute or half-hourly generation from your inverter. If the model predicts a smooth bell and your real curve has a notch at 11:00 to 12:30, you have found a shadow.
A real-looking comparison for one clear day (6 December, 4 kWp, no optimisers):
Hour Model (kW) Actual (kW) Gap
09:00 0.18 0.17 -6%
10:00 0.62 0.55 -11%
11:00 0.95 0.61 -36%
12:00 1.08 0.74 -31%
13:00 0.99 0.93 -6%
14:00 0.58 0.56 -3%
Two hours of 30%+ gap, bracketed by agreement. A uniform “derate factor” would never reveal that. It would smear the error across the day and hide the cause.
Error source three: low-irradiance thresholds
Panels do not convert light linearly across all conditions. Below roughly 200 W/m2, efficiency falls, and the model you are using may or may not capture that. Datasheets give STC performance at 1000 W/m2, and many also give a low-irradiance figure at 200 W/m2 (typically 95% to 98% of STC efficiency for good modules, worse for budget ones).
The inverter matters more than most people expect:
- Start-up threshold. Many string inverters need a minimum DC voltage (often 100 V to 150 V) before they begin exporting. On a gloomy 8am in January, the array may be producing power at the panels but not delivering any to the house.
- Efficiency at low load. A 4 kW inverter running at 5% load (200 W) is less efficient than at 50%. European efficiency ratings weight this, but December operation lives permanently in that low-load zone.
- Oversizing helps. An array of 4.4 kWp on a 3.68 kW inverter clips a few hours in June but is more efficient in winter because the inverter sits nearer its sweet spot.
A model using a flat 14% to 16% system loss factor will be about right across the year on average and wrong in both directions at the extremes. That is exactly the pattern you do not want if you are sizing a battery on the shoulders.
A validation routine that takes an evening
Here is the process I would commit to. It needs only a spreadsheet and your inverter export.
- Export actuals. At least one full winter month, daily totals minimum, hourly if you can get them. Smart meter data from your supplier’s app or an IHD-linked tool like Octopus’s Home Mini and the Octopus API gives you import and export, which lets you back out generation if you also have a CT clamp or inverter figure.
- Run the model for the same dates using actual weather, not a typical year. PVGIS TMY is for planning, not validation. Use measured irradiance (Open-Meteo’s historical API is free and has hourly shortwave radiation) so you are testing the physics, not the weather luck.
- Compute the error for each day, then classify days: clear, mixed, overcast. A simple rule: clear if the daily GHI is above 80% of clear-sky, overcast if below 30%.
- Read the pattern.
Day type Days Mean model error
Clear 5 +4%
Mixed 14 +11%
Overcast 12 +27%
If the overcast error dominates, the problem is diffuse handling or low-light thresholds. If clear days are off by hour, it is shading. If everything is uniformly high by about 10%, you probably have a soiling, degradation or system-loss issue, not a sky issue.
- Only then fix the model. Change one thing at a time: transposition model, horizon, low-light curve. Re-run. Stop when the mean absolute error for December and January is under about 10% on a monthly basis.
What this does to your decisions
A model that passes this test earns the right to answer expensive questions. Say your validated January generation is 52 kWh and your daytime base load averages 0.4 kW, roughly 5 kWh across daylight hours per day, or 155 kWh in the month. A battery will have almost nothing to store from solar in January: the array rarely exceeds the house’s demand. The January value of a battery is tariff arbitrage (charging cheaply overnight on something like Octopus Intelligent Go), not solar shifting. A summer-validated model would have told you the battery pays back through solar surplus. The winter one tells you that story is mostly June.
If your model cannot say that, it is not ready to be priced against.
For the wider method behind choosing inputs, resolution and tools, the pillar guide on forecasting what your roof will actually generate covers the full workflow. Use it, then bring the result back here and break it against December.
Run the routine on your own November data this week. It is the first month in which the sun is low enough to show you what you have built, and by the time February arrives you will have four months of ground truth that no summer comparison could give you.